Запис Детальніше

Upgrading of the high-current accelerator “Tonus”

Vernadsky National Library of Ukraine

Переглянути архів Інформація
 
 
Поле Співвідношення
 
Title Upgrading of the high-current accelerator “Tonus”
 
Creator Ryabchikov, A.I.
Petrov, A.V.
Karpov, V.B.
Polkovnikova, N.M.
Tolmacheva, V.G.
Usov, Yu.P.
 
Description In the paper presented, the new technical development of the high-current electron accelerator “Tonus-NT” (Tomsk nanosecond accelerator – new technologies) is described. It has been developed taking into account the experience of 30-years exploitation of the previous analogue – the accelerator “Tonus”. The scheme of the accelerator includes the high-voltage transformer with resonant contours (Tesla transformer) charging the double forming line filled with the transformer oil and the high-voltage diode. The gas-filled trigatron spark gap with up to 10 atm operating pressure is used for the double forming line switching. The main accelerator parameters are as follows: accelerating voltage range 0.4-1.7 MeV, line impedance 36.6 Ω, pulse duration 60 ns, pulse repetition rate up to 10 pps.
 
Date 2015-03-30T06:39:07Z
2015-03-30T06:39:07Z
2001
 
Type Article
 
Identifier Upgrading of the high-current accelerator “Tonus” / A.I. Ryabchikov, A.V. Petrov, V.B. Karpov, N.M. Polkovnikova, V.G. Tolmacheva, Yu.P. Usov // Вопросы атомной науки и техники. — 2001. — № 3. — С. 35-37. — Бібліогр.: 6 назв. — англ.
1562-6016
PACS numbers: 29.17.+w
http://dspace.nbuv.gov.ua/handle/123456789/79227
 
Language en
 
Relation Вопросы атомной науки и техники
 
Publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України