Application of CdTe (CdZnTe) detectors for radioactive waste characterization
Vernadsky National Library of Ukraine
Переглянути архів ІнформаціяПоле | Співвідношення | |
Title |
Application of CdTe (CdZnTe) detectors for radioactive waste characterization
|
|
Creator |
Dovbnya, N.A.
Karasyov, S.P. Kutny, V.E. Rybka, A.V. Shlyakhov, I.N. Uvarov, V.L. |
|
Subject |
Application of the nuclear methods
|
|
Description |
The radiation detectors based on wide-zone semiconductor CdTe (CdZnTe) monocrystals have promising advantages for their application in investigation (characterization) of radioactive waste. Among these advantages there are the wide range of photons flux and energy, high registration efficiency and satisfactory energy resolution without deep cooling of the detector. This report discusses the obtained data concerning radiation stability of detectors, influence of different conditions (filters, collimators, registration channel fill etc.) on their energy resolution in spectrometric regime, as well as a dependence of radionuclide identification accuracy on detector size.
|
|
Date |
2015-04-12T06:14:46Z
2015-04-12T06:14:46Z 2002 |
|
Type |
Article
|
|
Identifier |
Application of CdTe (CdZnTe) detectors for radioactive waste characterization / N.A. Dovbnya, S.P. Karasyov, V.E. Kutny, A.V. Rybka, I.N. Shlyakhov, V.L. Uvarov // Вопросы атомной науки и техники. — 2002. — № 2. — С. 55-57. — Бібліогр.: 3 назв. — англ.
1562-6016 PACS 07.85.-m, 07.88.+y, 81.70.Jb http://dspace.nbuv.gov.ua/handle/123456789/80114 |
|
Language |
en
|
|
Relation |
Вопросы атомной науки и техники
|
|
Publisher |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
|
|