The paper presents a framework for the analysis of the three-phased inverter functioning in linear modulated regime with weak inductive charge in triangle connection. The resistive – inductive charge with a power factor cosφ > 0,55 is defined as weak inductive. The recovery time of the reactive energy accumulated in the charge’s inductances is smaller than tact (an interval from a period). On the circuits configurated in the pulses of a tact one determines their equations in transitory regime and their solutions, and on the basis of some recurrent relations for the other tacts one determines the waveforms of the voltages and electric currents for a period. |
|