Plastic scintillators for thermal neutrons detection
Vernadsky National Library of Ukraine
Переглянути архів ІнформаціяПоле | Співвідношення | |
Title |
Plastic scintillators for thermal neutrons detection
|
|
Creator |
Nemchenok, I.B.
Gundorin, N.A. Shevchik, E.A. Shurenkova, A.A. |
|
Subject |
Characterization and properties
|
|
Description |
The new cadmium and gadolinium-loaded polymethylmethacrylate based plastic scintillators with the mass fraction of the metals up to 2 % and 4 %, respectively, are described in this article. There are presented the techniques of the new materials preparation and their main properties: transmission spectra, light output and thermal neutrons detection efficiency. The light output of Cd -loaded scintillator with 2 % of metal is 67 % relative to the unloaded sample; the light output of Gd -loaded plastic scintillator with 4 % of the metal is reduced to 67.6 %. There is regular increase of the thermal neutrons detection efficiency for the both series of the scintillation materials.
|
|
Date |
2017-06-11T06:06:39Z
2017-06-11T06:06:39Z 2013 |
|
Type |
Article
|
|
Identifier |
Plastic scintillators for thermal neutrons detection / I.B. Nemchenok, N.A. Gundorin, E.A. Shevchik, A.A. Shurenkova // Functional Materials. — 2013. — Т. 20, № 3. — С. 310-314. — Бібліогр.: 16 назв. — англ.
1027-5495 DOI: dx.doi.org/10.15407/fm20.03.310 http://dspace.nbuv.gov.ua/handle/123456789/120083 |
|
Language |
en
|
|
Relation |
Functional Materials
|
|
Publisher |
НТК «Інститут монокристалів» НАН України
|
|