ДИАГНОСТИКА МОМЕНТАЛЬНЫХ ТЕПЛОВЫХ БАЛАНСОВ ПЕЧИ ДЛЯ АНАЛИЗА ЭФФЕКТИВНОСТИ ТЕПЛОТЕХНИЧЕСКИХ ПАРАМЕТРОВ
Електронний архів E-archive DonNTU – (Electronic archive Donetsk National Technical University)
Переглянути архів ІнформаціяПоле | Співвідношення | |
Title |
ДИАГНОСТИКА МОМЕНТАЛЬНЫХ ТЕПЛОВЫХ БАЛАНСОВ ПЕЧИ ДЛЯ АНАЛИЗА ЭФФЕКТИВНОСТИ ТЕПЛОТЕХНИЧЕСКИХ ПАРАМЕТРОВ
Diagnosis of Instant Heat Balances for the Analysis of the Furnace Thermal Parameters Efficiency Діагностика моментальних теплових балансів печі для аналізу ефективності теплотехнічних параметрів |
|
Creator |
Скоробогатова, И.В.
Бирюков, А.Б. Гавриленко, Б.В. Skorobogatova, I. Biryukov, A. Gavrylenko, B. Скоробогатова, І.В. Бірюков, О.Б. Гавриленко, Б.В. |
|
Subject |
паливо
датчики режим управління піч діагностика ефективність sensors fuel position control furnace diagnostics efficiency топливо управление печь диагностика эффективность |
|
Description |
We analyze thermal parameters that affect the quality of billet heating in the chamber furnace. Dynamic equations were obtained during primary heating and during exposure of metal in the furnace. In the heat treatment chamber furnaces blanks controlled variable to implement diagnostics is the surface temperature of the material. It was determined that the normalized measure of the quality of the heating is heated by the thermal state of the billet At a certain approach to the installation of the sensors is possible to study the asymmetry of heat within the furnace. Measure the surface temperature of heated bodies in the furnace chamber pyrometers is a daunting technical challenge. A disadvantage of the known system of automatic control is the absence of current information about the actual heating of the metal. The use of a heat meter in the automatic control system will evaluate the current heat absorption of the metal and keep heating for a given temperature regime map. Increasing the value of the fuel utilization factor and reduce gas consumption can be achieved by lowering the temperature of flue gases. The problem can be solved by increasing the convective heat transfer coefficient or emissivity. It has been studied experimentally. It has been found that the use of pulsed mode will increase the heat transfer coefficient by 30-35% and to reduce the heating time by 15-20%. The implementation of the requirements of energy-saving technology to increase fuel efficiency requires a change in the number of operations in the automation of the furnace, and thus changes the functionality of the system being developed. This in turn complicates the concept of separate blocks and links and the use of additional control circuits. Enhanced functionality, improving performance of the furnace requires a change in the structure of the automation system thermal furnace. Проведен анализ теплотехнических параметров, влияющих на качество нагрева заготовок в камерной печи. Получены динамические уравнения в периоды основного нагрева и выдержки металла в печи. |
|
Date |
2013-09-17T10:16:54Z
2013-09-17T10:16:54Z 2013 |
|
Type |
Article
|
|
Identifier |
Наукові праці Донецького національного технічного університету. Серія: Обчислювальна техніка та автоматизація. Випуск 2 (25). - Донецьк, ДонНТУ, 2013. С - 57-63
2075-4272 УДК 681.513.7 http://ea.donntu.edu.ua/handle/123456789/22629 |
|
Publisher |
Донецький національний технічний університет
|
|