Запис Детальніше

ОЦІНЮВАННЯ ЕЛЕКТРОМАГНІТНОЇ СУМІСНОСТІ ЗА НЕСИНУСОЇДАЛЬНОСТІ НАПРУГИ У ДІЮЧИХ МЕРЕЖАХ

Електронний архів E-archive DonNTU – (Electronic archive Donetsk National Technical University)

Переглянути архів Інформація
 
 
Поле Співвідношення
 
Title ОЦІНЮВАННЯ ЕЛЕКТРОМАГНІТНОЇ СУМІСНОСТІ ЗА НЕСИНУСОЇДАЛЬНОСТІ НАПРУГИ У ДІЮЧИХ МЕРЕЖАХ
Evaluation of Electromagnetic Compatibility for Nonsinusoidal Voltage in Functioning Networks
Оценивание электромагнитной совместимости по несинусоидальности напряжения в действующих сетях
 
Creator ДМИТРІЄВА, О.М.
ЛАРІНА, І.І.
ЛЮТИЙ, О.П.
DMITRIEVA, E.
LARINA, I
LYUTY, A.
ДМИТРИЕВА, Е.Н.
ЛАРИНА, И.И.
ЛЮТЫЙ, А.П.
 
Subject ЭМС
несинусоидальность
корреляционная функция
спектральная плотность
синусоидальная и несинусоидальная компоненты
воздействие на конденсаторную установку
EMC
nonsinusoidality
correlation function
spectral density
sinusoidal and nonsinusoidal components
the capacitor installation’s influence
несинусоїдальність
кореляційна функція
спектральна щільність
синусоїдальна і несинусоїдальна компоненти
вплив на конденсаторну установку
 
Description Voltage unsinusoidality causes the additional losses of active power and reduction of electrical equipment service life. For the estimation of these effects it is necessary to select two components from voltage oscillogram: sinusoidal (SC) with frequency 50 Hz and nonsinusoidal (NSC). For periodic processes this task is decided unequivocally: by decomposition in the Fourier series. However in operating electric networks the processes are unperiodical. The notion “harmonic” is absent for them. Therefore the estimation of EMC by “harmonics” and “interharmonics” is mathematically incorrect, and task of separation the components is theoretically indefinite. The methods of elimination of uncertainty are considered in the article, and the estimation of EMS of the condenser setting is as an example given. The spectral density of voltage is used in the first method of SC separation. Such possibility is conditioned that in a neighbourhood of frequency 50 Hz the very narrow impulse is observed on the density graphic. It is considered the spectral density of SC. The spectral density of NSC is determined as a difference of densities. In the second method the SK is separated by a narrow-band filter on frequency 50 Hz with subsequent compensation of phase shift. In the absence of low-frequency distortions it is suggested to use continuous averaging of voltage on an interval no more than 0,01 s without a phase shift. Reduction of process ordinates after averaging is compensated by their division into the amplitude-phase characteristic value of averaging window at frequency 50 Hz. NSC is determined by subtraction of obtained SC from an initial process. The condenser setting is designed as three series connected links: proportional, forced and oscillatory. EMC is estimated by effective current, which must not exceed 130 % from rated. The effective current and its components are calculated on the appropriate spectral densities either on SC or NSC of voltage. In last case it is recommended to use the method of partial reactions, where the model of condenser setting is offered by two in- parallel inertia links of the first order. An example of EMC estimation of the condenser setting during work of arc steel- making furnace is given.
Розглядається задача оцінювання ЕМС при неперіодичних спотвореннях синусоїдальної напруги. Показується невизначеність понять синусоїдальної і несинусоїдальної компонент. Пропонуються засоби усунення невизначеності: шляхом виділення синусоїдальної складової кореляційної функції або попереднього осереднення кривої напруги. Приводиться приклад оцінювання ЕМС конденсаторної установки.
 