Title ВЕКТОРНОЕ УПРАВЛЕНИЕ АКТИВНЫМ КОРРЕКТОРОМ КОЭФФИЦИЕНТА МОЩНОСТИ
Векторне керування активним коректором коефіцієнта потужності
Vector Control of the Active Corrector of Power Factor
 
Creator КОРОЛЬ, С.В.
KOROL, S.
 
Subject active corrector
power factor
reactive power
vector control
three-phase pulse-width converter
DC link
активний коректор
коефіцієнт потужності
реактивна потужність
векторне керування
ланка постійного струму
трифазний широтно-імпульсний перетворювач
активный корректор
коэффициент мощности
реактивная мощность
векторное управление
трехфазный широтно-импульсный преобразователь
звено постоянного тока
 
Description Power factor correction reduces the power losses in power networks, reduces the network load, improves power quality, and, therefore, increases the lifetime and performance of electric devices connected to the network. Active correctors can smoothly adjust the reactive power, reaching full power factor correction. Implementation of vector methods for active compensator control can improve performance and accuracy of control comparative with the scalar control methods. A new nonlinear vector control algorithm for three- phase bridge converter, which operates in reactive power compensation mode, was proposed. Design made for the full nonlinear model of three-phase inverter in the vector voltage oriented coordinate system. The proposed algorithm consists of: double circuit system of voltage stabilization in the DC link, and of input current reactive component control subsystem, which does not depend of the voltage stabilization in the DC link. The analytical dependences for dynamics error of converter input current reactive component and voltage in the DC link are obtained. It is shown that asymptotic stability of converter input current reactive component control subsystem is achieved. Converter input current reactive component control error depends on the rate of reference change and at a constant reference goes to zero. The theoretical conclusions are confirmed by computer simulation using the full nonlinear model of pulse-width converter. Simulation has shown that the proposed algorithm corrects the leading and the lagging power factor. Control error of input current reactive component attenuates to zero for 0.2 seconds. Error voltage regulation in the DC link does not exceed 10 volts. As a result, is proposed solution, which provides independent control of input current reactive component with stabilizing the voltage in the DC link simultaneously.
Предложен новый алгоритм векторного управления трехфазным мостовым преобразователем, который работает в режиме компенсации реактивной мощности. Синтез и исследование выполнялось с использованием полной нелинейной модели широтноимпульсного преобразователя. Показано, что алгоритм обеспечивает асимптотическое регулирование реактивной компоненты входного тока преобразователя.
 