Запис Детальніше

РОЗРАХУНОК ВИХІДНИХ ПАРАМЕТРІВ МАТЕМАТИЧНОЇ МОДЕЛІ СИНХРОННОГО ГЕНЕРАТОРА В ФАЗНИХ КООРДИНАТАХ

Електронний архів E-archive DonNTU – (Electronic archive Donetsk National Technical University)

Переглянути архів Інформація
 
 
Поле Співвідношення
 
Title РОЗРАХУНОК ВИХІДНИХ ПАРАМЕТРІВ МАТЕМАТИЧНОЇ МОДЕЛІ СИНХРОННОГО ГЕНЕРАТОРА В ФАЗНИХ КООРДИНАТАХ
Calculation of Initial Parameters of Mathematical Model of Synchronous Generator in Phase Coordinates
Расчет исходных данных параметров математической модели синхронного генератора в фазных координатах
 
Creator РУДЕВІЧ, Н.В.
ПІСКУРЬОВ, М.Ф.
RUDEVICH, N.
PISKUREV, M.
РУДЕВИЧ, Н.В.
ПИСКУРЕВ, М.Ф.
 
Subject математическая модель
синхронный генератор
фазные координаты
mathematical model
synchronous generator
phase coordinate
математична модель
синхронний генератор
фазні координати
 
Description The article is devoted to calculation of initial parameters of mathematical model of the salient pole synchronous generator
with damping windings in phase coordinates. Initial parameters of mathematical model of the synchronous generator
are revealed. The parameters of mathematical model, which are absent in help data, are called. Expressions for
determination of own inductance and mutual inductance of phases of windings of a stator of mathematical model
according to help data of the synchronous generator are given. Formulas for calculation of own inductance and mutual
inductance of a winding of excitement of the mathematical model given to a stator winding are defined. Settlement
expressions of own inductance and mutual inductance of damping windings on a cross and longitudinal axis of the
mathematical model given to a stator winding are given. Expressions for calculation of active resistance of a winding of
excitement of mathematical model are considered at a working temperature and the stator given to a winding. Formulas
for determination of active resistance of a winding of a stator of mathematical model are written down at a working
temperature. Settlement formulas of active resistance of damping windings are determined by a longitudinal and cross
axis of mathematical model at a working temperature. Expression for calculation of constant inertia of the synchronous
generator, and also voltage of a winding of excitement of mathematical model is written down. The formula of
recalculation of active resistance to working temperature is given. The expressions considered in article for
determination of initial parameters of mathematical model of the salient pole synchronous generator with damping
windings are given in phase coordinates for cases when modeling is carried out in called units or in relative units under
nominal conditions of the generator.
В статті розглянуто розрахунок вихідних параметрів математичної моделі синхронного генератора з демпферними обмотками в фазних координатах.
 